XTRA-GUARD® 1 Multipair Foil Shield



  Product Code Conductor
Size AWG
Conductor
Size mm2
Conductor Stranding
No./mm
No. of
Pairs
Insulation
Thickness
Nominal
Diameter
Jacket
Thickness
Reel
Length
Feet
  8580200 24 0.23 7 x 0.2 1 0.25 4.06 0.81 100
  8580201 24 0.23 7 x 0.2 2 0.25 5.49 0.81 100
  8580202 24 0.23 7 x 0.2 3 0.25 5.79 0.81 100
  8580203 24 0.23 7 x 0.2 4 0.25 6.27 0.81 100
  8580204 24 0.23 7 x 0.2 5 0.25 6.81 0.81 100
  8580205 24 0.23 7 x 0.2 6 0.25 7.37 0.81 100
  8580206 24 0.23 7 x 0.2 9 0.25 8.53 0.81 100
  8580207 24 0.23 7 x 0.2 11 0.25 9.17 0.81 100
  8580208 24 0.23 7 x 0.2 15 0.25 10.29 0.81 100
  8580209 24 0.23 7 x 0.2 19 0.25 11 0.81 100
  8580210 24 0.23 7 x 0.2 27 0.25 13.11 0.81 100
  8580211 22 0.35 7 x 0.25 1 0.25 4.37 0.81 100
  8580212 22 0.35 7 x 0.25 2 0.25 5.99 0.81 100
  8580213 22 0.35 7 x 0.25 3 0.25 6.32 0.81 100
  8580214 22 0.35 7 x 0.25 4 0.25 6.88 0.81 100
  8580215 22 0.35 7 x 0.25 5 0.25 7.49 0.81 100
  8580216 22 0.35 7 x 0.25 6 0.25 8.13 0.81 100
  8580217 22 0.35 7 x 0.25 9 0.25 9.45 0.81 100
  8580218 22 0.35 7 x 0.25 11 0.25 10.16 0.81 100
  8580219 22 0.35 7 x 0.25 15 0.25 11.46 0.81 100
  8580220 22 0.35 7 x 0.25 19 0.25 12.27 0.81 100
  8580221 22 0.35 7 x 0.25 27 0.25 15.72 1.35 100
CHARACTERISTICS:
Jacket Colour: Slate
Jacket Material: Extra-Premium Grade PVC
Colour Code: 24, 22 AWG Chart B
Conductor: Stranded Tinned Copper
Insulation: Colour-Coded Premium PVC
Shield: Aluminum/Polyester Foil Facing in with Stranded Tinned Copper Drain Wire Equal in Size to Insulated Conductors of Cable

SPECIFICATIONS:
UL AWM Style 2464 Overall
UL AWM Style 10002 Conductors, 24 & 22 AWG
CSA CMG FT4
Voltage Rating: 300 Volt

Operating Temperature:
-30°C to 105°C CM & CMG
-30°C to 80°C AWM 2464
Passes UL VW-1 Flame Test
Passes CSA FT4 Flame Test
RoHS Compliant
CE Approved

XTREME PERFORMANCE BENEFITS:
  • Unique Premium-Grade PVC Insulation And Jacket Provides Easier Routing Of Cables In Tight Spaces

  • Fast, Easy Stripping Of Insulation And Jacket To Reduce Installation And Connectorization Time And Cost

  • Light-Duty Resistance To Most Oils Per UL Class 43

  • Resistance To Ambient Temperatures Up To 105°C

  • Ultraviolet uV Stabilized

    XTRA-GUARD® 1 APPLICATIONS:
  • EIA RS 232C Interface

  • High Technology Applications in Controlled Environments

  • Medical Electronics

  • Point-Of-Sale Equipment

  • Computer Peripherals

  • Industrial Process Controls

    Keywords: wire, cable, alpha, extra guard, xtraguard, multicore, high performance, robitics, power, signal, protection, flexing