This page requires Javascript to be enabled.
Customer Services: +44 (0)1202 865222

XTRA-GUARD® 1 Multicore Foil Shield



  Product Code Conductor
Size AWG
Conductor
Size mm2
Conductor Stranding
No./mm
No. of
Conductors
Insulation
Thickness
Nominal
Diameter
Jacket
Thickness
Reel
Length
Feet
  8580050 24 0.23 7 x 0.2 2 0.25 4.06 0.81 100
  8580051 24 0.23 7 x 0.2 3 0.25 4.24 0.81 100
  8580052 24 0.23 7 x 0.2 4 0.25 4.55 0.81 100
  8580053 24 0.23 7 x 0.2 6 0.25 5.21 0.81 100
  8580054 24 0.23 7 x 0.2 8 0.25 5.56 0.81 100
  8580055 24 0.23 7 x 0.2 10 0.25 6.3 0.81 100
  8580056 24 0.23 7 x 0.2 15 0.25 6.98 0.81 100
  8580057 24 0.23 7 x 0.2 20 0.25 7.72 0.81 100
  8580058 24 0.23 7 x 0.2 25 0.25 8.53 0.81 100
  8580059 24 0.23 7 x 0.2 30 0.25 8.99 0.81 100
  8580060 24 0.23 7 x 0.2 40 0.25 10.01 0.81 100
  8580061 24 0.23 7 x 0.2 50 0.25 11 0.81 100
  8580062 24 0.23 7 x 0.2 60 0.25 11.89 0.81 100
  8580063 24 0.23 7 x 0.2 70 0.25 12.83 0.81 100
  8580064 22 0.35 7 x 0.25 2 0.25 4.37 0.81 100
  8580065 22 0.35 7 x 0.25 3 0.25 4.57 0.81 100
  8580066 22 0.35 7 x 0.25 4 0.25 4.9 0.81 100
  8580067 22 0.35 7 x 0.25 6 0.25 5.66 0.81 100
  8580068 22 0.35 7 x 0.25 8 0.25 6.07 0.81 100
  8580069 22 0.35 7 x 0.25 10 0.25 6.91 0.81 100
  8580070 22 0.35 7 x 0.25 15 0.25 7.7 0.81 100
CHARACTERISTICS:
Jacket Colour: Slate
Jacket Material: Extra-Pr emium Grade PVC
Colour Code: 24, 22 AWG Chart E
Conductor: Stranded Tinned Copper
Insulation : Colour-Coded Premium PVC
Shield : Aluminum/Polyester Foil Facing in with Stranded Tinned Copper Drain Wire Equal in Size to Insulated Conductors of Cable

SPECIFICATIONS:
UL Type CM, AWM Style 2464 Overall
UL AWM Style 10002 Conductors
CSA CMG FT4
Voltage Rating: 300 Volt

Operating Temperature:
-30°C to 105°C CM & CMG
-30°C to 80°C AWM 2464
Passes UL VW-1 Flame Test
Passes CSA FT4 Flame Test
RoHS Compliant
CE Approved

XTREME PERFORMANCE BENEFITS:
  • Unique Premium-Grade PVC Insulation And Jacket Provides Easier Routing Of Cables In Tight Spaces

  • Fast, Easy Stripping Of Insulation And Jacket To Reduce Installation And Connectorization Time And Cost

  • Light-Duty Resistance To Most Oils Per UL Class 43

  • Resistance To Ambient Temperatures Up To 105°C

  • Ultraviolet uV Stabilized

    XTRA-GUARD® 1 APPLICATIONS:
  • EIA RS 232C Interface 24, 22 AWG

  • High Technology Applications in Controlled Environments

  • Medical Electronics

  • Point-Of-Sale Equipment

  • Computer Peripherals

  • Industrial Process Controls

    Keywords: wire, cable, alpha, extra guard, xtraguard, multicore, high performance, robitics, power, signal, protection, flexing