This page requires Javascript to be enabled.
Customer Services: +44 (0)1202 865222

Tri-Rated Single Core PVC Insulated Wire



  Product Code ColourNominal Conductor
Area
mm2
Nominal
Conductor
Stranding #/mm
Current Rating
Amps
Nominal Voltage Drop
mV/A/m
Nominal O/DReel
Length
Metres
  8520000-01 White 0.5 16/0.2 11 46 2.6 100
  8520000-02 Black 0.5 16/0.2 11 46 2.6 100
  8520000-03 Red 0.5 16/0.2 11 46 2.6 100
  8520000-05 Yellow 0.5 16/0.2 11 46 2.6 100
  8520000-06 Blue 0.5 16/0.2 11 46 2.6 100
  8520000-07 Brown 0.5 16/0.2 11 46 2.6 100
  8520000-08 Orange 0.5 16/0.2 11 46 2.6 100
  8520000-09 Grey 0.5 16/0.2 11 46 2.6 100
  8520000-12 Green/Yellow 0.5 16/0.2 11 46 2.6 100
  8520001-01 White 0.75 24/0.2 14 31 2.8 100
  8520001-02 Black 0.75 24/0.2 14 31 2.8 100
  8520001-03 Red 0.75 24/0.2 14 31 2.8 100
  8520001-05 Yellow 0.75 24/0.2 14 31 2.8 100
  8520001-06 Blue 0.75 24/0.2 14 31 2.8 100
  8520001-07 Brown 0.75 24/0.2 14 31 2.8 100
  8520001-08 Orange 0.75 24/0.2 14 31 2.8 100
  8520001-09 Grey 0.75 24/0.2 14 31 2.8 100
  8520001-12 Green/Yellow 0.75 24/0.2 14 31 2.8 100
  8520002-01 White 1.0 32/0.2 17 22 3 100
  8520002-02 Black 1.0 32/0.2 17 22 3 100
  8520002-03 Red 1.0 32/0.2 17 22 3 100
  8520002-05 Yellow 1.0 32/0.2 17 22 3 100
  8520002-06 Blue 1.0 32/0.2 17 22 3 100
  8520002-07 Brown 1.0 32/0.2 17 22 3 100
  8520002-08 Orange 1.0 32/0.2 17 22 3 100
  8520002-09 Grey 1.0 32/0.2 17 22 3 100
  8520002-12 Green/Yellow 1.0 32/0.2 17 22 3 100
  8520003-01 White 1.5 30/0.25 21 15 3.3 100
  8520003-02 Black 1.5 30/0.25 21 15 3.3 100
  8520003-03 Red 1.5 30/0.25 21 15 3.3 100
Specifications:
Standards: In accordance with BS6231 TypeCK
Conforms to UL subject 758 Appliance Wiring Material AWM for style 1015
Canadian Standards Association CSA approved. Complies with standard C22.2 No.127, Type TEW
Conductors: Flexible Class 5 conductors to BS6360
Insulation: PVC insulation. Flame retardant to BS EN 60332-1-2 and VW-1
Temp Rating: BS6231 specifies a maximum continuous conductor operating temperature of 90°C, and for limited use up to 105°C UL and CSA rated 105°C
Voltage Rating: 600/1000V BS , 600V UL & CSA

RoHS Directive 2002/95/EC compliant

Note:
Current ratings are based on a conductor operating temperature of 85°C and an ambient air temperature of 45°C and assumes single cable isolated in free air. The ratings do not apply if the cable is protected by a semi-enclosed fuse to BS3036. The voltage drop figures quoted are for one cable only. For other circuit arrangements they should be adjusted as follows:
Single phase 50Hz a.c. or 2-wire d.c. x 2
Three phase a.c. x 1.732
Application: For the internal wiring of appliances and also the wiring for switch, control, metering and instrument panels of power switchgear.

Keywords: wire, cable, single, core, hook up, connection, equipment, electrical, pvc